Stable Operation LITTELFUSE with SL-1026-275 Holdover Voltage 150mS
Product Details:
Place of Origin: | China |
Brand Name: | JULUN |
Certification: | UL |
Model Number: | SL1026 |
Payment & Shipping Terms:
Minimum Order Quantity: | 100 |
---|---|
Price: | 2~5USD |
Packaging Details: | carton |
Delivery Time: | 3~4weeks |
Payment Terms: | T/T |
Supply Ability: | 100000PCS/day |
Detail Information |
|||
Glow Voltage: | Glow Voltage: | Insulation Resistance: | > 10GΩ At 100 Volts |
---|---|---|---|
Part Marking: | Color Coded Body SL1026-275: Black/Black SL1026-400: Black/Yellow SL1026-700: Black/Red | Glow ToArc Transition Current:: | ~1 Amp |
Applications: | Cell Phone Base Statio | Capacitance: | <=2.5pf, 1MHz 0 Volts Bias |
Arc Voltage: | ~35 Volts, On State Voltage At 1 Amp (Depending On Voltage Type) | Holdover Voltage: | <150mS, Tested At 130 Volts According To ITU-T Rec. K.12 & REA PE 80 |
Highlight: | Stable Operation LITTELFUSE,150mS LITTELFUSE,SL-1026-275 LITTELFUSE |
Product Description
Product Description:
Gas Discharge Tube is a type of electrical component that utilizes gas plasma to protect electronic devices from overvoltage and overcurrent. It is designed to operate in a wide range of temperatures, making it suitable for various applications.
The Gas Discharge Tube can withstand extreme temperatures ranging from -40°C to +90°C, ensuring reliable operation even in harsh environments.
The Gas Discharge Tube has an arc voltage of ~35 Volts, with an on-state voltage of 1 Amp, depending on the voltage type. This feature makes it ideal for protecting electronic devices from high voltage fluctuations.
With a low capacitance of <=2.5pf at 1MHz and 0 Volts bias, the Gas Discharge Tube minimizes the effect of parasitic capacitance on the circuits, ensuring high-speed data transmission and accurate signal processing.
The Gas Discharge Tube is commonly used in cell phone base stations, providing reliable protection for the sensitive electronic components of these devices.
The Gas Discharge Tube has a glow to arc transition current of ~1 Amp, indicating the point at which it switches from a low-current glow discharge state to a high-current arc discharge state. This feature ensures that the Gas Discharge Tube can handle high current surges without damage.
The Gas Discharge Tube is equipped with SL-1026-7008 control gear, which provides precise control over the discharge process, ensuring optimal performance and longevity of the device.
The Gas Discharge Tube is designed to handle high voltage fluctuations, making it an ideal choice for protecting electronic devices from voltage spikes and surges.
Features:
- Product Name: Gas Discharge Tube
- Holdover Voltage: <150mS, Tested At 130 Volts According To ITU-T Rec. K.12 & REA PE 80
- Materials:
- Electrode Base: Nickel Iron Alloy
- Electrode Plating: Nickel
- Body: Ceramic
- Insulation Resistance: > 10GΩ At 100 Volts
- Applications: Cell Phone Base Station, Communications Control, Communication Equipment, Trackside Cabinets
- Capacitance: <=2.5pf, 1MHz 0 Volts Bias
Technical Parameters:
Part Marking | Color Coded Body |
---|---|
Weight | 11g (0.388 Oz.) |
Glow Voltage | SL1026-275: Black/Black SL1026-400: Black/Yellow SL1026-700: Black/Red |
Capacitance | <=2.5pf, 1MHz 0 Volts Bias |
Insulation Resistance | > 10GΩ At 100 Volts |
Applications | Cell Phone Base Station, Transit Rail System |
Arc Voltage | ~35 Volts, On State Voltage At 1 Amp (Depending On Voltage Type) |
Glow to Arc Transition Current | ~1 Amp |
Materials | Electrode Base: Nickel Iron Alloy Electrode Plating: Nickel Body: Ceramic |
Holdover Voltage | <150mS, Tested At 130 Volts According To ITU-T Rec. K.12 & REA PE 80 |
Part Marking | SL-1026-400 |
---|---|
Weight | 11g (0.388 Oz.) |
Glow Voltage | SL1026-275: Black/Black SL1026-400: Black/Yellow SL1026-700: Black/Red |
Capacitance | <=2.5pf, 1MHz 0 Volts Bias |
Insulation Resistance | > 10GΩ At 100 Volts |
Applications | Cell Phone Base Station, Transit Rail System |
Arc Voltage | ~35 Volts, On State Voltage At 1 Amp (Depending On Voltage Type) |
Glow to Arc Transition Current | ~1 Amp |
Materials | Electrode Base: Nickel Iron Alloy Electrode Plating: Nickel Body: Ceramic |
Holdover Voltage | <150mS, Tested At 130 Volts According To ITU-T Rec. K.12 & REA PE 80 |
Applications:
Brand Name: JULUN
Model Number: SL1026
Place of Origin: China
Materials:
- Electrode Base: Nickel Iron Alloy
- Electrode Plating: Nickel
- Body: Ceramic
Part Marking:
- Color Coded Body
- SL1026-275: Black/Black
- SL1026-400: Black/Yellow
- SL1026-700: Black/Red
Glow to Arc Transition Current: ~1 Amp
Holdover Voltage: <150mS, Tested At 130 Volts According To ITU-T Rec. K.12 & REA PE 80
Arc Voltage: ~35 Volts, On State Voltage At 1 Amp (Depending On Voltage Type)
The JULUN SL1026 Gas Discharge Tube is a highly reliable and efficient product that is designed to protect transit rail systems from lightning strikes and power surges. As a vital component of transit rail system safety, the SL1026-400 model is specifically engineered to provide superior protection against high voltage surges.
Transit rail systems are constantly exposed to external environmental factors such as lightning strikes and power surges. Without proper protection, these events can cause significant damage to the transit rail system, leading to costly repairs and downtime. The JULUN SL1026 Gas Discharge Tube is the perfect solution to prevent these events from happening.
With its advanced design and high-quality materials, the SL1026-400 model is able to withstand high voltage surges and provide a smooth transition to arc current. The ceramic body and nickel iron alloy electrodes ensure long-lasting durability and reliable performance. The color-coded body also makes it easy to identify and install the correct model for specific voltage requirements.
The SL1026-400 model has been extensively tested and meets international standards for transit rail system safety, including ITU-T Rec. K.12 and REA PE 80. It has a low holdover voltage of less than 150mS, ensuring quick response time to protect the transit rail system. The arc voltage is also kept at a minimum of ~35 Volts, providing efficient and effective protection without causing any disruptions to the system.
Overall, the JULUN SL1026 Gas Discharge Tube is an essential product for any transit rail system. Its reliable performance, durability, and adherence to international safety standards make it the top choice for lightning protection and surge protection. Choose JULUN SL1026 for a safe and efficient transit rail system.
Customization:
JULUN Gas Discharge Tube SL1026 is a heavy-duty transient suppresser designed for reliable protection against voltage spikes and surges. It is suitable for use in various applications such as trackside cabinets and other industrial equipment.
The Gas Discharge Tube SL1026 has a high insulation resistance of more than 10GΩ at 100 volts, ensuring safe and efficient operation.
- Electrode Base: Nickel Iron Alloy
- Electrode Plating: Nickel
- Body: Ceramic
The use of high-quality materials in the construction of the Gas Discharge Tube SL1026 ensures durability and reliability even in harsh environments.
The Gas Discharge Tube SL1026 is designed to withstand a wide range of temperatures, making it suitable for use in various industrial settings.
- Color Coded Body
- SL1026-275: Black/Black
- SL1026-400: Black/Yellow
- SL1026-700: Black/Red
To make identification and installation easier, the Gas Discharge Tube SL1026 is marked with color-coded bodies for different voltage ratings. The SL1026-275 is marked with a black body and black band, the SL1026-400 with a black body and yellow band, and the SL1026-700 with a black body and red band.
For a complete protection solution, the Gas Discharge Tube SL1026 can be used with the 1053 Holder, providing secure and easy mounting options for a variety of applications.
Packing and Shipping:
The Gas Discharge Tube is packaged in a sturdy cardboard box to ensure safe delivery. Each tube is individually wrapped in protective packaging to prevent any damage during transit.
For bulk orders, the tubes are packed in larger boxes and secured with bubble wrap and packing peanuts to provide extra protection.
Our shipping methods include air freight and sea freight, depending on the customer's preference and location. We also offer express delivery for urgent orders.
Customers can choose their preferred shipping carrier and we will arrange for the delivery of the Gas Discharge Tubes to their desired destination.
All packages are labeled with the product name, quantity, and any necessary handling instructions to ensure proper handling and delivery.
We take great care in packaging and shipping our Gas Discharge Tubes to ensure they arrive at their destination in perfect condition.
For any special packaging or shipping requests, please contact our customer service team and we will do our best to accommodate your needs.
FAQ:
- Q: What is the brand name of this product?
- A: The brand name of this product is JULUN.
- Q: What is the model number of this product?
- A: The model number of this product is SL1026.
- Q: Where is this product manufactured?
- A: This product is manufactured in China.
- Q: What is the main function of this product?
- A: The main function of this product is to protect electronic devices from overvoltage.
- Q: What is the size of this product?
- A: The size of this product is determined by the type of gas discharge tube used, but it is generally small and compact.